Series 5000 Entry System Installation/Operation Manual
5-4 151174
5.3.2 Standby Electrical Voltages
Table 5-1 shows the correct standby voltages for the various terminals on the 5083/5084
Control Panel.
5.3.3 System Messages
This section lists the possible error massages that may be seen at the 5083/5084 Control Panel.
(See Table 5-2.)
Table 5-1: 5083/5084 Standby Voltages
Between
Terminals
Voltage
1 to 2 16.5 VAC
8 to 11 8 - 9 VDC
9 to 11 8 - 9 VDC
10 to 11 12 - 14 VDC
11 to 12 12 - 14 VDC
11 to 13 .8 - .9 VDC
11 to 14 .8 - .9 VDC
Table 5-2: Error Messages and Meanings
System Message Meaning
TRY AGAIN This message will display during programming, if the entered data is out of range, or has too
many or to few characters. During user operation this message will appear to indicate that a user
is not found.
NO ROOM TO ADD User information memory location is full. System can have up to 1000 users.
NOT AUTHORIZED This message will appear during user operation if the user code or aux relay is not enabled and it
is attempted to be used.
SYSTEM TIMEOUT This message indicates the call time length has expired.
INVALID CODE If an incorrect user or access code is entered this message will display.
!!CODE TAMPER!! If four consecutive invalid access or user codes have been entered the alarm relay will energize
and this message will be displayed.