Installation Instructions
151174 3-17
3.5.9 Installing an AC Doorstrike
1. Install the electric doorstrike in the door frame according to the manufacturers specifica-
tions.
Figure 3-11 AC Doorstrike Wiring Diagram
2. Wire a transformer (24 VAC maximum) in series with the door strike opener, to terminals
4 and 5. (See Figure 3-11.)
Note: Do Not use the transformer that powers the 5083 or 5084 control panel. All AC doorstrikes must be pow-
ered by a separate AC transformer. The maximum voltage rating of the door strikes contacts is 250VAC @
1A. Do Not install a reverse bias diode across the coil.
3.5.10 Doorstrike Reset Switch
In installation sites requiring a magnetic contact to re-lock a door prior to the expiration of the
programmed time (“DOOR TIME”—see section 4.2.1 step 22) use the following steps.
1. Wire the contact to terminals 8 and 11. (See Figure 3-10 or Figure 3-11.)
2. The contact must be in the open state when the magnet is next to it.