Series 5000 Entry System Installation/Operation Manual
4-2 151174
4.1 Entering, Changing Options and Exiting
Operating Modes
This section contains information that will help you enter, exit and change different selections
in the various operating modes.
4.1.1 To enter an operating mode:
1. Press * followed by the operating mode number (0 through 6). See Table 4-1 for choices.
The display will show ACCESS #.
2. Enter the 6-digit access code. (Factory default is 123456.)
3. Press *.
4.1.1.1 If The Access Code Is Not Known:
1. Turn the power switch to the “off” position.
2. Press and hold the 0 key on the keypad while turning the power switch back to the “on”
position. The system will power up in the programming mode. The display will show
ACCESS # 123456 (see section 4.1.1).
4.1.2 To Change a Selection.
1. Press # to clear display.
2. Enter new data.
If the programming field your in has pre-selected choices, press any number key (0-9) to
toggle through the selections.
3. When the display shows the choice you want, Press *.
4.1.3 To Skip a Selection.
To skip a step without changing the selection of the option:
Press *.
4.1.4 To Exit Any Operating Mode.
1. Press # #.